Prices incl. GST
Out of Stock.
- Product Code: CH-9370-P
- MPN: 9370-P
Specification
Electrical characteristics Supply voltage: 3.3 V
Sleep current typical: 0.1 μA
Sleep current maximum: 0.3 μA
Temperature sensor
Operational range: -40 ~ +85 ºC Full accuracy range: 0 ~ +65 ºC
Accuracy: ±1 ºC (range 0 ºC ~ +65 ºC)
Response time: 1.65 seconds (63% response from +30 to +125 °C).
Typical consumption: 1 μA measuring
Humidity sensor
Measurement range: 0 ~ 100% of relative humidity (for temperatures < 0 °C and > 60 °C see figure below)
Accuracy: < ±3% RH (at 25 ºC, range 20 ~ 80%)
Hysteresis: ±1% RH
Operating temperature: -40 ~ +85 ºC
Response time (63% of step 90% to 0% or 0% to 90%): 1 second
Typical consumption: 1.8 μA measuring
Maximum consumption: 2.8 μA measuring
Pressure sensor
Measurement range: 30 ~ 110 kPa
Operational temperature range: -40 ~ +85 ºC
Full accuracy temperature range: 0 ~ +65 ºC
Absolute accuracy: ±0.1 kPa (0 ~ 65 ºC)
Typical consumption: 2.8 μA measuring
Maximum consumption: 4.2 μA measuring